| Return Shipping Will Be Paid By | Buyer |
| All Returns Accepted | Returns Accepted |
| Item Must Be Returned Within | 30 Days |
| Refund Will Be Given As | Money Back |
| Brand | Crown |
| MPN | 45610 - 130367 |
Crown 45610 C-10 Cad Cell Eye Only (No Leads) Cad Cell Flame Detector These flame detectors are hand crafted and tested twice, once before assembly, and after. The C-10 is a direct replacement in the Honeywell C554A, Honeywell replacement cell part numbers 130367, 120320 and 124607. Made of a hermetic glass to metal seal, and cadmium sulfide for sensing, you’ll find this sensor to be the best of it’s kind. Used On Most Standard Oil Burners Like Beckett, Carlin, Wayne, Clean Burn, Energylogic, Lanair Using A C554 Style Cad Cell Assembly. Replaces Westwood E81, Type M, E81-5, Type M, CleanBurn 33116-E, Clean Burn 33116-E, Honeywell 130367, 120320 and 124607, Oilco OC-10, Oilco OC10, Carlin 4002400A Fits Honeywell C554A1018, C554A1026, C554A1083, C554A1109, C554A1133, C554A1174, C554A1215, C554A1216, C554A1232, C554A1372, C554A1463, C554A1570, C554A1687, C554A1703, C554A1760, C554A1794, C554A1836, C554A1844, C554A1893, C554A1919, C554A1927, Beckett 7006U, 7135U -Specifications-Maximum Voltage: 30 VACMax. cell surface temp.: 180 degrees FahrenheitMethod of sensing: Cadmium SulfideMax. resistance: Min. 300 OHMSDurning firing: Max. 1,600 OHMS